  The main topics of VISION FM Series batteries on this page are
 
  • General Specifications
  • General Features
  • Battery Construction
  • Charge characteristics
  Battery Types
 
 
  1
 
Products Search
Advanced Search
  Location here: Home / Products / FM Series  
 

VISION FM series are designed for general-purpose applications, such as UPS, telecom, and electrical utilities.
With 10 years design life, the batteries comply to the most popular international standards, such as IEC896-2, BS6290-4, Eurobat Guide.
The battery container and cover are available both in V0 class flame retardant ABS or HBO ABS plastics.
With more than 15 years of production experience, VISION FM series of VRLA batteries are recognized as the most reliable and high quality battery system in the industry.

Product Standards
You can expect our batteries meet with the standards JIS, DIN, IEC & BS6290-4. We have obtained ISO9001 & ISO14001 certification. We have obtained UL approval (MH25860) for all types of batteries. We have obtained CE approval for all types of batteries. All these render our batteries to be compatible with requirements of world-level equipments.

Main Application
Engine starting, Communication equipment; Fire & security systems; Uninterruptible power supplies; Telecommunication systems; Electronic cash registers; Electronic test equipment; processor based office machines; Control equipment; Electric powered bicycle and wheelchairs; Geophysical equipment; Marine equipment; Medical equipment; Portable cine & video lights; Power tools Solar powered systems; Television& video recorders; Vending machines; Other standby or primary power supplies .

 

General Specifications Click the ico to Maximize or Minimize the table of battery specifications

 
Type Nominal Voltage
(V)
Capacity
(Ah)
Dimension(mm/Kg[(±5%)]) Dimension(Inch/Poud[(±5%)]) Terminal
Length width Height Total Heigh Weight Length Width Height Total Heigh Weight
3FM180D-X 6 180 306 168 220 225 28.6 12.05 6.61 8.66 8.86 63.1 F12
3FM225S-AM 6 225 260 180 247 267 31 10.24 7.09 9.72 10.51 68.3 F20
3FM225-X 6 225 320 176 225 230 30.5 12.60 6.93 8.86 9.06 67.3 M8
6FM7.2 12 7.2 151 65 94 100 2.5 5.94 2.56 3.70 3.94 5.51 F2
6FM17-X 12 17 181 77 167 167 5.7 7.13 3.03 6.57 6.57 12.6 M5
6FM24-X 12 24 166 175 125 125 8.6 6.54 6.89 4.92 4.92 19 M5
6FM33-X 12 33 195 130 155 168 10.2 7.68 5.12 6.10 6.61 22.5 M6
6FM40-X 12 40 197 165 170 170 13.5 7.76 6.50 6.69 6.69 29.8 M6
6FM45-X 12 45 197 165 170 170 13.8 7.76 6.50 6.69 6.69 30.4 M6
6FM55SG-X 12 55 229 138 208 213 19.5 9.02 5.43 8.19 8.39 43 M6
6FM55S-X 12 55 224 132 205 210 18 8.82 5.20 8.07 8.27 39.7 F11
6FM55-X 12 55 239 132 205 210 18 9.41 5.20 8.07 8.27 39.75 F11
6FM60B-X 12 60 258 166 206 211 24 10.16 6.54 8.11 8.31 52.9 F11
6FM60-X 12 60 258 166 206 215 24 10.16 6.54 8.11 8.46 52.9 M6
6FM65-X 12 65 350 167 179 179 23.4 13.78 6.57 7.05 7.05 51.6 M6
6FM80-X 12 72 350 167 179 179 24 13.78 6.57 7.05 7.05 52.9 M6
6FM75-X 12 75 258 166 206 215 24 10.16 6.54 8.11 8.46 52.9 M6
6FM90T-X 12 89 306 169 210 215 30 12.05 6.65 8.27 8.46 66.1 F21
6FM100F-X 12 100 330 171 215 222 30 12.99 6.73 8.46 8.74 66.2 M8
6FM100-X 12 100 330 171 215 220 32 12.99 6.73 8.46 8.66 70.6 M8
6FM100HX 12 100 330 171 215 222 32 12.99 6.73 8.46 8.74 70.5 F11
6FM120-X 12 120 410 176 227 227 38 16.14 6.93 8.94 8.94 83.8 M8
6FM120HX 12 120 410 176 227 227 38 16.14 6.93 8.94 8.94 83.8 F12
6FM134-X 12 134 342 172 273 277 42.5 13.46 6.77 10.75 10.91 93.7 F15
6FM150HX 12 150 485 172 240 240 47 19.09 6.77 9.45 9.45 103.6 F12
6FM150-X 12 150 485 172 240 240 47 19.09 6.77 9.45 9.45 104 M8
6FM180SHX 12 180 522 238 218 223 62 20.55 9.37 8.58 8.78 136.7 F12
6FM200S-X 12 200 522 238 218 223 65 20.55 9.37 8.58 8.78 143 M8
6FM200SHX 12 200 522 238 218 223 65 20.55 9.37 8.58 8.78 143.3 F12
6FM230-X 12 230 520 269 203 208 72.6 20.47 10.59 7.99 8.19 160.1 F12
expand or shrink the table of batery specificatons

 

General Features

Higher Reliability and Quality

Throughout the whole manufacturing process, PPM and ISO 9001 are carried out to make sure that the product reliability and defect ratio meet with the PPM standard.

Higher Power Density

A special assembly technology is used to enhance power density to a considerable level.

Reliable Construction

The extra strong construction ABS container reduces case bulging and plate warping, ensuring long life and high performance.

Valve regulating
Perfect venting system, which operates under low pressure, is designed to release excess gas and keep the internal pressure within the optimum range of safe and efficient performance.

Excellent Recovery from Deep Discharge

Unique technical processes are used into the grid alloy and electrolyte additives, so that the battery can be recharged easily to a normal level even after being over-discharged.

Living Up to Prevailing Standards
The batteries live up to standards JIS, DIN, BS and IEC.

 
 

Construction
These reactions can take place only by using :

  • Plates composed of special alloy with several components which provide the plate grids with high mechanical strength and a high level of hydrogen over voltage.
  • An appropriate ratio between positive and negative active materials.
  • Fiberglass separators manufactured from borosilicate, giving them excellent resistance to high temperatures and to sulphuric acid. The high level of porosity of these separators is used to retain the quantity of electrolyte necessary for cell operation, but without any free electrolyte.
  • A pressure relief valve which allows gas to be released if necessary in the case of an accidental overcharge.
 

Charge Characteristics
The cells in the VISION FM product range must be charged at a constant voltage at an ambient temperature of 20oC, the batteries should be charged at 2.27-2.30 volts per cell. It is not necessary to limit the current, as this will be governed by the maximum output available from the charger until the voltage limit is reached. The charging voltage of 2.27-2.30 volts should also be used for float charging. To achieve nominal performance characteristics, it is recommended to adjust this value to suit the ambient temperature, as indicated in the following table: Under these conditions a full recharge will be completed in approximately 48 hours.

Fast recharge:
Increasing the charge voltage to 2.40 Volts per cell can reduce recharge time and it is possible, depending on the depth of discharge, to halve the recharge time. Under these conditions, however, the charge must be monitored and must be terminated when the charge current remains reasonably steady for 3 hours
after the voltage limit has been reached. At the beginning of charge the current must be limited to 0.3C10 (A).

Ripple current:
The ripple content of the charging current affects the life of the battery. It is recommended to limit the continuous ripple current to 0.05 C10 (in amperes) as recommended value (never exceed 0.10C10). Transient and other ripple type voltage excursions can be accommodated provided that, with the battery disconnected, the system peak to peak voltage including regulation limits falls within 2.5% of the recommended float voltage of the battery.

 
FM
 

Home | Products | Support | About us | Contact | Sitemap | Chinese
© 2006 VISION Group, All Rights Reserved.
Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel:+86-755-8431 8088 Fax:+86-755-8431 8038 E-mail: Sales@vision-batt.com